Case Plastic, black (PA), diameter 40 mm
Accuracy 2.5 % relative to the end value of the measuring range (5 % - 95 % of the measuring range)
Measuring ranges 0 ... 10 to 0 ... 250 bar
Pressure limitation Steady: 3/4 x end value of measuring range Fluctuating: 2/3 x end value of measuring range Short time: End value of measuring range
Permissible temperature Ambient: -20 … +60 °C Medium: +60 °C maximum
|
Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): Max. ±0.4 %/10 K of the measuring span
Process connection Cu-alloy, G ¼ (male)
Pressure element Cu-alloy
Ingress protection IP 41 per EN 60529 / lEC 529
|